NR 661.1033 HistoryHistory: CR 19-082: cr. Register August 2020 No. 776, eff. 9-1-20; renum. (1) (a) to (1) under s. 13.92 (4) (b) 7., Stats., and correction in (14) (a) 2., 3., (b) 2. made under s. 35.17, Stats., Register August 2020 No. 776; correction in (14) (a) 1., (b) 1. made under s. 13.92 (4) (b) 7., Stats., Register April 2021 No. 784.
NR 661.1034NR 661.1034Test methods and procedures.
NR 661.1034(1)(1)A remanufacturer or other person that stores or treats hazardous secondary material subject to the provisions of this subchapter shall comply with the test methods and procedural requirements provided in this section.
NR 661.1034(2)(2)When a closed-vent system is tested for compliance with no detectable emissions, as required under s. NR 661.1033 (12), the test shall comply with all of the following requirements:
NR 661.1034(2)(a)(a) Monitoring shall comply with Reference Method 21 in appendix A of 40 CFR part 60, incorporated by reference in s. NR 660.11.
NR 661.1034(2)(b)(b) The detection instrument shall meet the performance criteria of Reference Method 21 in appendix A of 40 CFR part 60, incorporated by reference in s. NR 660.11.
NR 661.1034(2)(c)(c) The instrument shall be calibrated before use on each day of its use by the procedures specified in Reference Method 21 in appendix A of 40 CFR part 60, incorporated by reference in s. NR 660.11.
NR 661.1034(2)(d)(d) Calibration gases shall be:
NR 661.1034(2)(d)1.1. Zero air of less than 10 ppm of hydrocarbon in air.
NR 661.1034(2)(d)2.2. A mixture of methane or n-hexane and air at a concentration of approximately, but less than, 10,000 ppm methane or n-hexane.
NR 661.1034(2)(e)(e) The background level shall be determined as set forth in Reference Method 21 in appendix A of 40 CFR part 60, incorporated by reference in s. NR 660.11.
NR 661.1034(2)(f)(f) The instrument probe shall be traversed around all potential leak interfaces as close to the interface as possible as described in Reference Method 21 in appendix A of 40 CFR part 60, incorporated by reference in s. NR 660.11.
NR 661.1034(2)(g)(g) The arithmetic difference between the maximum concentration indicated by the instrument and the background level shall be compared with 500 ppm for determining compliance.
NR 661.1034(3)(3)Performance tests to determine compliance with s. NR 661.1032 (1) and with the total organic compound concentration limit specified in s. NR 661.1033 (3) shall comply with all of the following:
NR 661.1034(3)(a)(a) Performance tests to determine total organic compound concentrations and mass flow rates entering and exiting control devices shall be conducted and data reduced in accordance with all of the following reference methods and calculation procedures:
NR 661.1034(3)(a)1.1. Method 2 in appendix A of 40 CFR part 60, incorporated by reference in s. NR 660.11, for velocity and volumetric flow rate.
NR 661.1034(3)(a)2.2. Method 18 or Method 25A in appendix A of 40 CFR part 60, incorporated by reference in s. NR 660.11, for organic content. If Method 25A is used, the organic HAP used as the calibration gas shall be the single organic HAP representing the largest percent by volume of the emissions. The use of Method 25A is acceptable if the response from the high-level calibration gas is at least 20 times the standard deviation of the response from the zero calibration gas when the instrument is zeroed on the most sensitive scale.
NR 661.1034(3)(a)3.3. Each performance test shall consist of 3 separate runs. Each run shall be conducted for at least 1 hour under the conditions that exist when the hazardous secondary material management unit is operating at the highest load or capacity level reasonably expected to occur. For the purpose of determining total organic compound concentrations and mass flow rates, the average of results of all runs shall apply. The average shall be computed on a time-weighted basis.
NR 661.1034(3)(a)4.4. Total organic mass flow rates shall be determined by one of the following equations:
NR 661.1034(3)(a)4.a.a. For sources utilizing Method 18.
Where:
Eh= Total organic mass flow rate, kg/h
Q2sd= Volumetric flow rate of gases entering or exiting control device, as determined by Method 2, dscm/h
n = Number of organic compounds in the vent gas
Ci= Organic concentration in ppm, dry basis, of compound i in the vent gas, as determined by Method 18
MWi= Molecular weight of organic compound i in the vent gas, kg/kg-mol
0.0416 = Conversion factor for molar volume, kg-mol/m3 (@293 K and 760 mm Hg)
10-6 = Conversion from ppm
NR 661.1034(3)(a)4.b.b. For sources utilizing Method 25A.
Where:
Eh= Total organic mass flow rate, kg/h
Q = Volumetric flow rate of gases entering or exiting control device, as determined by Method 2, dscm/h
C = Organic concentration in ppm, dry basis, as determined by Method 25A
MW = Molecular weight of propane, 44
0.0416 = Conversion factor for molar volume, kg-mol/m3 (@293 K and 760 mm Hg)
10-= Conversion from ppm.
NR 661.1034(3)(a)5.5. The annual total organic emission rate shall be determined by the following equation:
Where:
E= Total organic mass emission rate, kg/y
E= Total organic mass flow rate for the process vent, kg/h
H = Total annual hours of operations for the affected unit, h
NR 661.1034(3)(a)6.6. Total organic emissions from all affected process vents at the facility shall be determined by summing the hourly total organic mass emission rates, Eh, as determined in subd. 4., and by summing the annual total organic mass emission rates, EA, as determined in subd. 5., for all affected process vents at the facility.
NR 661.1034(3)(b)(b) The remanufacturer or other person that stores or treats the hazardous secondary material shall record process information that may be necessary to determine the conditions of the performance tests. Operations during periods of startup, shutdown, and malfunction may not constitute representative conditions for the purpose of a performance test.
NR 661.1034(3)(c)(c) The remanufacturer or other person that stores or treats the hazardous secondary material at an affected facility shall provide, or cause to be provided, all of the following performance testing facilities:
NR 661.1034(3)(c)1.1. Sampling ports adequate for the test methods specified in par. (a).
NR 661.1034(3)(c)2.2. Safe sampling platform.
NR 661.1034(3)(c)3.3. Safe access to sampling platform.
NR 661.1034(3)(c)4.4. Utilities for sampling and testing equipment.
NR 661.1034(3)(d)(d) For the purpose of making compliance determinations, the time-weighted average of the results of the 3 runs required in par. (a) 3. shall apply. In the event that a sample is accidentally lost or conditions occur in which one of the 3 runs must be discontinued because of forced shutdown, failure of an irreplaceable portion of the sample train, extreme meteorological conditions, or other circumstances beyond the control of the remanufacturer or other person that stores or treats the hazardous secondary material, compliance may, upon the department’s approval, be determined using the average of the results of the 2 other runs.
NR 661.1034(4)(4)To show that a process vent associated with a hazardous secondary material distillation, fractionation, thin-film evaporation, solvent extraction, or air or steam stripping operation is not subject to the requirements of this subchapter, the remanufacturer or other person that stores or treats the hazardous secondary material shall make an initial determination that the time-weighted, annual average total organic concentration of the material managed by the hazardous secondary material management unit is less than 10 ppmw using one of the following 2 methods:
NR 661.1034(4)(a)(a) Direct measurement of the organic concentration of the material using all of the following procedures:
NR 661.1034(4)(a)1.1. The remanufacturer or other person that stores or treats the hazardous secondary material shall take a minimum of 4 grab samples of material for each material stream managed in the affected unit under process conditions expected to cause the maximum material organic concentration.
NR 661.1034(4)(a)2.2. For material generated on-site, the grab samples shall be collected at a point before the material is exposed to the atmosphere such as in an enclosed pipe or other closed system that is used to transfer the material after generation to the first affected distillation, fractionation, thin-film evaporation, solvent extraction, or air or steam stripping operation. For material generated off-site, the grab samples shall be collected at the inlet to the first material management unit that receives the material, provided the material has been transferred to the facility in a closed system such as a tank truck and the material is not diluted or mixed with other material.
NR 661.1034(4)(a)3.3. Each sample shall be analyzed and the total organic concentration of the sample shall be computed using Method 9060A of “Test Methods for Evaluating Solid Waste, Physical/Chemical Methods,” EPA Publication SW-846, incorporated by reference in s. NR 660.11, or analyzed for its individual organic constituents.
NR 661.1034(4)(a)4.4. The arithmetic mean of the results of the analyses of the 4 samples shall apply for each material stream managed in the unit in determining the time-weighted, annual average total organic concentration of the material. The time-weighted average shall be calculated using the annual quantity of each material stream processed and the mean organic concentration of each material stream managed in the unit.
NR 661.1034(4)(b)(b) Using knowledge of the material to determine that its total organic concentration is less than 10 ppmw. Documentation of the material determination is required. Examples of documentation that shall be used to support a determination under this provision include production process information documenting that no organic compounds are used, information that the material is generated by a process that is identical to a process at the same or another facility that has previously been demonstrated by direct measurement to generate a material stream having a total organic content less than 10 ppmw, or prior speciation analysis results on the same material stream where it can also be documented that no process changes have occurred since that analysis that could affect the material total organic concentration.
NR 661.1034(5)(5)The determination that distillation, fractionation, thin-film evaporation, solvent extraction, or air or steam stripping operations manage hazardous secondary material with time-weighted, annual average total organic concentrations less than 10 ppmw shall be made by the remanufacturer or other person in accordance with all the following:
NR 661.1034(5)(a)(a) By the effective date that the facility becomes subject to the provisions of this subchapter or by the date when the material is first managed in a hazardous secondary material management unit, whichever is later.
NR 661.1034(5)(b)(b) Annually for continuously generated material, or whenever there is a change in the material being managed or a change in the process that generates or treats the material.
NR 661.1034(6)(6)When a remanufacturer or other person that stores or treats the hazardous secondary material and the department do not agree on whether a distillation, fractionation, thin-film evaporation, solvent extraction, or air or steam stripping operation manages a hazardous secondary material with organic concentrations of at least 10 ppmw based on knowledge of the material, the dispute may be resolved by using direct measurement as specified in sub. (4) (a).
NR 661.1034 HistoryHistory: CR 19-082: cr. Register August 2020 No. 776, eff. 9-1-20; correction in (1), (2) (a), (4) (a) 3. made under s. 35.17, Stats., Register August 2020 No. 776.
NR 661.1035NR 661.1035Recordkeeping requirements.
NR 661.1035(1)(a)(a) A remanufacturer or other person that stores or treats the hazardous secondary material subject to the provisions of this subchapter shall comply with the recordkeeping requirements of this section.
NR 661.1035(1)(b)(b) A remanufacturer or other person that stores or treats the hazardous secondary material of more than one hazardous secondary material management unit subject to the provisions of this subchapter may comply with the recordkeeping requirements for these hazardous secondary material management units in one recordkeeping system if the system identifies each record by each hazardous secondary material management unit.
NR 661.1035(2)(2)A remanufacturer or other person that stores or treats the hazardous secondary material shall keep all of the following records on-site:
NR 661.1035(2)(a)(a) For facilities that comply with the provisions specified in s. NR 661.1033 (1), an implementation schedule that includes dates by which the closed-vent system and control device will be installed and in operation. The schedule shall also include a rationale of why the installation cannot be completed at an earlier date. The implementation schedule shall be kept on-site at the facility by the effective date that the facility becomes subject to the provisions of this subchapter.
NR 661.1035(2)(b)(b) Up-to-date documentation of compliance with the process vent standards specified in s. NR 661.1032, including all of the following:
NR 661.1035(2)(b)1.1. Information and data identifying all affected process vents, annual throughput and operating hours of each affected unit, estimated emission rates for each affected vent and for the overall facility, and the approximate location within the facility of each affected unit, such as identifying the hazardous secondary material management units on a facility plot plan.
NR 661.1035(2)(b)2.2. Information and data supporting determinations of vent emissions and emission reductions achieved by add-on control devices based on engineering calculations or source tests. For the purpose of determining compliance, determinations of vent emissions and emission reductions shall be made using operating parameter values, such as temperatures, flow rates, or vent stream organic compounds and concentrations, that represent the conditions that result in maximum organic emissions, such as when the hazardous secondary material management unit is operating at the highest load or capacity level reasonably expected to occur. If the remanufacturer or other person that stores or treats the hazardous secondary material takes any action, such as managing a material of different composition or increasing operating hours of affected hazardous secondary material management units, that would result in an increase in total organic emissions from affected process vents at the facility, then a new determination is required.
NR 661.1035(2)(c)(c) When a remanufacturer or other person that stores or treats the hazardous secondary material chooses to use test data to determine the organic removal efficiency or total organic compound concentration achieved by the control device, a performance test plan shall be developed and include all of the following:
NR 661.1035(2)(c)1.1. A description of how it is determined that the planned test is going to be conducted when the hazardous secondary material management unit is operating at the highest load or capacity level reasonably expected to occur. This shall include the estimated or design flow rate and organic content of each vent stream and define the acceptable operating ranges of key process and control device parameters during the test program.
NR 661.1035(2)(c)2.2. A detailed engineering description of the closed-vent system and control device including all of the following:
NR 661.1035(2)(c)2.a.a. Manufacturer’s name and model number of control device.
NR 661.1035(2)(c)2.b.b. Type of control device.
NR 661.1035(2)(c)2.c.c. Dimensions of the control device.
NR 661.1035(2)(c)2.e.e. Construction materials.
NR 661.1035(2)(c)3.3. A detailed description of sampling and monitoring procedures, including sampling and monitoring locations in the system, the equipment to be used, sampling and monitoring frequency, and planned analytical procedures for sample analysis.
NR 661.1035(2)(d)(d) Documentation of compliance with s. NR 661.1033 including all of the following information:
NR 661.1035(2)(d)1.1. A list of all information references and sources used in preparing the documentation.
NR 661.1035(2)(d)2.2. Records, including the dates, of each compliance test required under s. NR 661.1033 (11).
NR 661.1035(2)(d)3.3. If engineering calculations are used, a design analysis, specifications, drawings, schematics, and piping and instrumentation diagrams based on the appropriate sections of “APTI Course 415: Control of Gaseous Emissions,” incorporated by reference in s. NR 660.11, or other engineering texts acceptable to the department that present basic control device design information. Documentation provided by the control device manufacturer or vendor that describes the control device design in accordance with this subdivision may be used to comply with this requirement. The design analysis shall address the vent stream characteristics and control device operation parameters as follows:
NR 661.1035(2)(d)3.a.a. For a thermal vapor incinerator, the design analysis shall consider the vent stream composition, constituent concentrations, and flow rate. The design analysis shall also establish the design minimum and average temperature in the combustion zone and the combustion zone residence time.
NR 661.1035(2)(d)3.b.b. For a catalytic vapor incinerator, the design analysis shall consider the vent stream composition, constituent concentrations, and flow rate. The design analysis shall also establish the design minimum and average temperatures across the catalyst bed inlet and outlet.
NR 661.1035(2)(d)3.c.c. For a boiler or process heater, the design analysis shall consider the vent stream composition, constituent concentrations, and flow rate. The design analysis shall also establish the design minimum and average flame zone temperatures, combustion zone residence time, and description of method and location where the vent stream is introduced into the combustion zone.